DCM
 
 
Tel: +86-571-86625003
Email1: info@optictrans.com
Email2: kally@optictrans.com
WhatsApp: +86 13967163428
Skype: hightech086
 
 
Keyword:
 
  Products
OPTP-F-FB Out-Door Tap 1-2-3-4 Way(Full power pass)
   Content
Features
1) Used for field trunk of CATV, good waterproof design
2) 75Ω, 5/8″KS-F trans-connector available
3) Aluminum alloy die casting shell, anti-corrosion paint-spray
4) Adapt to 5-1000MHZ
5) Metal isolation netting, prevention of RF interference, good shield function
6) All ports adapt to pass power: 6 or 10A AC/DC
 
Technical Parameters
1-way Tap
Item
Parameters
Tap Loss (dB)
Normal
06
08
10
12
14
16
18
20
Typical (Permissible Deviation)
5MHz
±1.0
5.6
7.2
9.2
11.3
13.8
15.4
17.4
19.4
50MHz
±1.0
5.7
7.3
9.6
11.9
14.0
15.6
17.6
19.6
550MHz
±1.0
5.9
7.6
9.6
12.1
14.0
16.0
18.0
19.0
750MHz
±1.0
6.2
7.8
9.8
12.0
14.2
16.1
18.2
20.1
1000MHz
±1.0
6.3
7.9
10.3
12.1
14.3
16.3
18.4
20.6
Insertion Loss (dB)
5MHz
≤3.5
≤2.9
≤2.2
≤1.7
≤1.5
≤1.2
≤1.1
≤1.0
50MHz
≤3.8
≤3.3
≤2.7
≤1.9
≤1.6
≤1.4
≤1.3
≤1.1
550MHz
≤4.0
≤3.5
≤3.0
≤2.4
≤1.8
≤1.5
≤1.4
≤1.3
750MHz
≤4.5
≤4.0
≤3.5
≤2.8
≤2.2
≤2.0
≤2.0
≤1.8
1000MHz
≤5.0
≤4.5
≤4.0
≤3.2
≤2.8
≤2.5
≤2.4
≤2.2
Reverse Isolation (dB)
5-50MHz
≥23
≥23
≥24
≥26
≥28
≥30
≥32
≥38
50-550MHz
≥22
≥20
≥24
≥26
≥26
≥28
≥31
≥31
550-750MHz
≥20
≥20
≥23
≥24
≥26
≥28
≥28
≥28
750-1000MHz
≥18
≥20
≥22
≥23
≥24
≥26
≥26
≥27
Return Loss (dB)
5-50MHz
≥18
≥20
≥20
≥22
≥22
≥22
≥22
≥22
50-550MHz
≥20
≥20
≥20
≥20
≥20
≥20
≥20
≥20
550-750MHz
≥16
≥17
≥17
≥17
≥17
≥17
≥17
≥17
750-1000MHz
≥16
≥16
≥16
≥16
≥16
≥16
≥16
≥16
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2-way Tap
Item
Parameters
Tap Loss (dB)
Normal
08
10
12
14
16
18
20
22
Typical (Permissible Deviation)
5MHz
±1.0
7.2
9.8
11.9
13.8
15.8
17.8
19.3
21.4
50MHz
±1.0
6.9
10.0
11.5
14.0
16.5
17.8
20.0
21.9
550MHz
±1.0
6.9
10.2
11.6
14.2
16.9
17.9
20.4
22.3
750MHz
±1.0
8.2
10.5
12.0
14.5
17.2
18.3
20.7
22.6
1000MHz
±1.0
8.6
10.7
12.3
14.6
17.4
18.7
21.0
22.8
Insertion Loss (dB)
5MHz
≤3.5
≤3.0
≤2.9
≤2.2
≤1.7
≤1.5
≤1.2
≤1.1
50MHz
≤3.8
≤3.4
≤3.2
≤2.7
≤1.9
≤1.6
≤1.4
≤1.3
550MHz
≤4.0
≤3.7
≤3.5
≤3.0
≤2.4
≤1.8
≤1.5
≤1.4
750MHz
≤4.5
≤4.1
≤4.0
≤3.5
≤2.8
≤2.2
≤2.0
≤2.0
1000MHz
≤5.0
≤4.6
≤4.5
≤4.0
≤3.2
≤2.8
≤2.5
≤2.3
Reverse Isolation (dB)
5-50MHz
≥23
≥23
≥23
≥26
≥26
≥30
≥32
≥34
50-550MHz
≥22
≥22
≥22
≥26
≥26
≥28
≥30
≥32
550-750MHz
≥20
≥20
≥20
≥24
≥24
≥28
≥28
≥30
750-1000MHz
≥18
≥20
≥20
≥23
≥24
≥26
≥26
≥27
Tap-Tap Isolation (dB)
5-50MHz
≥23
≥23
≥23
≥26
≥28
≥30
≥34
≥36
50-550MHz
≥22
≥22
≥22
≥24
≥26
≥28
≥32
≥32
550-750MHz
≥20
≥20
≥20
≥23
≥26
≥28
≥28
≥28
750-1000MHz
≥18
≥20
≥20
≥22
≥24
≥26
≥26
≥27
Return Loss (dB)
5-50MHz
≥18
≥20
≥20
≥22
≥22
≥22
≥22
≥22
50-550MHz
≥20
≥20
≥20
≥20
≥20
≥20
≥20
≥20
550-750MHz
≥16
≥17
≥17
≥17
≥17
≥17
≥17
≥17
750-1000MHz
≥16
≥16
≥16
≥16
≥16
≥16
≥16
≥16
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3-way Tap
Item

Parameters

Tap Loss (dB)
Normal
10
12
14
16
20
24
26
28
Typical (Permis, sible Deviation)
5MHz
±1.0
9.7
11.9
14.1
16.5
19.2
23.8
25.4
27.4
50MHz
±1.0
9.9
11.5
14.0
16.5
19.7
23.6
25.6
27.6
550MHz
±1.0
10.0
11.6
14.1
16.9
19.8
23.9
25.9
27.9
750MHz
±1.0
10.3
12.0
14.2
17.2
20.2
24.3
26.4
28.3
1000MHz
±1.0
10.8
12.3
14.1
17.2
20.8
24.6
26.7
29.6
Insertion Loss (dB)
5MHz
≤3.5
≤2.9
≤2.2
≤1.7
≤1.5
≤1.2
≤1.1
≤1.0
50MHz
≤3.8
≤3.2
≤2.7
≤1.9
≤1.6
≤1.4
≤1.3
≤1.1
550MHz
≤4.0
≤3.5
≤3.0
≤2.4
≤1.8
≤1.5
≤1.4
≤1.3
750MHz
≤4.5
≤4.0
≤3.5
≤2.8
≤2.2
≤2.0
≤2.0
≤1.8
1000MHz
≤5.0
≤4.5
≤4.0
≤3.2
≤2.8
≤2.5
≤2.4
≤2.2
Reverse Isolation (dB)
5-50MHz
≥23
≥23
≥24
≥26
≥28
≥30
≥32
≥38
50-550MHz
≥22
≥22
≥24
≥26
≥26
≥28
≥31
≥31
550-750MHz
≥20
≥20
≥23
≥24
≥26
≥28
≥28
≥28
750-1000MHz
≥18
≥20
≥22
≥23
≥24
≥26
≥26
≥27
Tap-Tap Isolation(dB)
5-50MHz
≥23
≥23
≥24
≥26
≥28
≥30
≥32
≥38
50-550MHz
≥22
≥22
≥24
≥26
≥26
≥28
≥31
≥31
550-750MHz
≥20
≥20
≥23
≥24
≥26
≥28
≥28
≥28
750-1000MHz
≥18
≥20
≥22
≥23
≥24
≥26
≥26
≥27
Return Loss (dB)
5-50MHz
≥18
≥20
≥20
≥22
≥22
≥22
≥22
≥22
50-550MHz
≥20
≥20
≥20
≥20
≥20
≥20
≥20
≥20
550-750MHz
≥16
≥17
≥17
≥17
≥17
≥17
≥17
≥17
750-1000MHz
≥16
≥16
≥16
≥16
≥16
≥16
≥16
≥16
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 4-way Tap
Item
Parameters
Tap Loss (dB)
Normal
10
12
14
16
20
24
26
28
Typical (Permissible Deviation)
5MHz
±1.0
9.7
11.9
14.1
16.5
19.2
23.8
25.4
27.4
50MHz
±1.0
9.9
11.5
14.0
16.5
19.7
23.6
25.6
27.6
550MHz
±1.0
10.0
11.6
14.1
16.9
19.8
23.9
25.9
27.9
750MHz
±1.0
10.3
12.0
14.2
17.2
20.2
24.3
26.4
28.3
1000MHz
±1.0
10.8
12.3
14.1
17.2
20.8
24.6
26.7
29.6
Insertion Loss (dB)
5MHz
≤3.5
≤2.9
≤2.2
≤1.7
≤1.5
≤1.2
≤1.1
≤1.0
50MHz
≤3.8
≤3.2
≤2.7
≤1.9
≤1.6
≤1.4
≤1.3
≤1.1
550MHz
≤4.0
≤3.5
≤3.0
≤2.4
≤1.8
≤1.5
≤1.4
≤1.3
750MHz
≤4.5
≤4.0
≤3.5
≤2.8
≤2.2
≤2.0
≤2.0
≤1.8
1000MHz
≤5.0
≤4.5
≤4.0
≤3.2
≤2.8
≤2.5
≤2.4
≤2.2
Reverse Isolation (dB)
5-50MHz
≥23
≥23
≥24
≥26
≥28
≥30
≥32
≥38
50-550MHz
≥22
≥22
≥24
≥26
≥26
≥28
≥31
≥31
550-750MHz
≥20
≥20
≥23
≥24
≥26
≥28
≥28
≥28
750-1000MHz
≥18
≥20
≥22
≥23
≥24
≥26
≥26
≥27
Tap-Tap Isolation(dB)
5-50MHz
≥23
≥23
≥24
≥26
≥28
≥30
≥32
≥38
50-550MHz
≥22
≥22
≥24
≥26
≥26
≥28
≥31
≥31
550-750MHz
≥20
≥20
≥23
≥24
≥26
≥28
≥28
≥28
750-1000MHz
≥18
≥20
≥22
≥23
≥24
≥26
≥26
≥27
Return Loss (dB)
5-50MHz
≥18
≥20
≥20
≥22
≥22
≥22
≥22
≥22
50-550MHz
≥20
≥20
≥20
≥20
≥20
≥20
≥20
≥20
550-750MHz
≥16
≥17
≥17
≥17
≥17
≥17
≥17
≥17
750-1000MHz
≥16
≥16
≥16
≥16
≥16
≥16
≥16
≥16
 
Hangzhou OpticTrans Communication Tech. Co., LTD.
Copyright © 2011-2017 杭州奥全通信技术有限公司

工业和信息化部备案管理系统网站 浙ICP备11039329号-1

浙公网安备33010602005244号